12 V 1 OGi 25 PPol
Description
BAE OGi block batteries are robust lead-acid batteries optimised for high discharge performance and are particularly suitable for bridging times ranging from a few minutes up to one hour.
They are used for uninterruptible power supplies (UPS), as starter batteries for emergency diesel generator sets, and for standby power supply in data and signalling systems for transport infrastructure, switchgear installations of utility companies, and other applications.
Construction
Positive electrode
Round grid plate with circular grid bars made of corrosion-resistant PbSb1.6SnSe alloy
Negative electrode
Grid plate in low-antimony alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l
Container
Transparent SAN (styrene-acrylonitrile), impact-resistant
Lid
SAN, grey-coloured
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Plugs
Labyrinth plugs for aerosol retention; optionally ceramic plugs or ceramic funnel plugs in accordance with DIN 40 740
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars with cross-sections of 90, 150 or 300 mm², or
flexible insulated copper cables with cross-sections of 35, 50, 70, 95 or 120 mm²
Protection class
IP25 according to DIN 40 050, protection against accidental contact in accordance with VBG 4
Charging
IU characteristic curve
Maximum current (Imax) possible without limitation
Float charge voltage
U = 2.23 V/cell ±1% between 10 °C and 55 °C
Temperature compensation: ΔU/ΔT = −0.003 V/K below 10 °C (monthly average)
Float charge current
20 mA/100 Ah up to a maximum of 60 mA/100 Ah at end of service life
Boost charge
U = 2.35 to 2.40 V/cell, time-limited
Charging time to 92%
6 hours at 1.5 × I10 initial current, 2.23 V/cell, after 80% C3 discharge
Discharge Characteristics
Reference temperature
20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below the current-dependent end-of-discharge voltages must be avoided
Maintenance
- Every 6 months: Check battery voltage, pilot block voltages and temperatures
- Every 12 months: Record battery voltage, block voltages and temperatures
Operating Characteristics
Service life
16 years at 20 °C
Water topping-up interval
More than 3 years
>1000
Self-discharge
Approx. 3% per month at 20 °C
Operating temperature
-20 °C to +55 °C
Recommended: 10 °C to 30 °C
Dimensions according to
DIN 40 737 Part 3
Standards and Safety
Testing standards
IEC 60896-11
Safety standard / ventilation
DIN EN 50272-2
Delivery
Batteries are not subject to ADR regulations (road transport), provided the conditions of Special Provision 598 (Chapter 3.3) are met.
Specifications
- Length at mm
- 272.00
- width at mm
- 205.00
- Height at mm
- 385.00
- Weight at kg
- 35.00
- Spannung
- 12
- Capacity Ah
- 25
- Manufacture
- BAE
Reviews (0)
There are no reviews yet.
12 V 1 OGi 25 PPol
Description
BAE OGi block batteries are robust lead-acid batteries optimised for high discharge performance and are particularly suitable for bridging times ranging from a few minutes up to one hour.
They are used for uninterruptible power supplies (UPS), as starter batteries for emergency diesel generator sets, and for standby power supply in data and signalling systems for transport infrastructure, switchgear installations of utility companies, and other applications.
Construction
Positive electrode
Round grid plate with circular grid bars made of corrosion-resistant PbSb1.6SnSe alloy
Negative electrode
Grid plate in low-antimony alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l
Container
Transparent SAN (styrene-acrylonitrile), impact-resistant
Lid
SAN, grey-coloured
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Plugs
Labyrinth plugs for aerosol retention; optionally ceramic plugs or ceramic funnel plugs in accordance with DIN 40 740
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars with cross-sections of 90, 150 or 300 mm², or
flexible insulated copper cables with cross-sections of 35, 50, 70, 95 or 120 mm²
Protection class
IP25 according to DIN 40 050, protection against accidental contact in accordance with VBG 4
Charging
IU characteristic curve
Maximum current (Imax) possible without limitation
Float charge voltage
U = 2.23 V/cell ±1% between 10 °C and 55 °C
Temperature compensation: ΔU/ΔT = −0.003 V/K below 10 °C (monthly average)
Float charge current
20 mA/100 Ah up to a maximum of 60 mA/100 Ah at end of service life
Boost charge
U = 2.35 to 2.40 V/cell, time-limited
Charging time to 92%
6 hours at 1.5 × I10 initial current, 2.23 V/cell, after 80% C3 discharge
Discharge Characteristics
Reference temperature
20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below the current-dependent end-of-discharge voltages must be avoided
Maintenance
- Every 6 months: Check battery voltage, pilot block voltages and temperatures
- Every 12 months: Record battery voltage, block voltages and temperatures
Operating Characteristics
Service life
16 years at 20 °C
Water topping-up interval
More than 3 years
>1000
Self-discharge
Approx. 3% per month at 20 °C
Operating temperature
-20 °C to +55 °C
Recommended: 10 °C to 30 °C
Dimensions according to
DIN 40 737 Part 3
Standards and Safety
Testing standards
IEC 60896-11
Safety standard / ventilation
DIN EN 50272-2
Delivery
Batteries are not subject to ADR regulations (road transport), provided the conditions of Special Provision 598 (Chapter 3.3) are met.
Specifications
- Length at mm
- 272.00
- width at mm
- 205.00
- Height at mm
- 385.00
- Weight at kg
- 35.00
- Spannung
- 12
- Capacity Ah
- 25
- Manufacture
- BAE