12 V 5 OGiV 125 PPol
Item No. 0368004
BAE OGiV batteries belong to the highest EUROBAT classification for maintenance-free lead-acid batteries, 12+ long life. For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right
Out of stock
Description
BAE OGiV batteries belong to the highest EUROBAT classification for maintenance-free lead-acid batteries, 12+ long life.
For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right choice.
They are used for standby power supply in telecommunications equipment, microwave radio stations, data and signalling systems in transport infrastructure, switchgear installations of utility companies, and other applications.
Round grid plate with circular grid bars made of corrosion-resistant PbCaSn alloy
Negative electrode
Grid plate in PbCaSn alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l, immobilised as GEL using fumed silica
Container
SAN (styrene-acrylonitrile) in proven battery quality, grey-coloured, UL 94 HB
Lid
SAN, grey-coloured, UL 94 HB
Optionally available in ABS (container and lid), compliant with UL 94 V-0
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Valve
One valve per cell with flame arrestor
Opening pressure approx. 100 mbar, closing pressure approx. 50 mbar
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars with cross-sections of 90, 150 or 300 mmÂČ, or
flexible insulated copper cables with cross-sections of 35, 50, 70, 95 or 120 mmÂČ
Protection class
IP25 according to DIN 40 050, protection against accidental contact in accordance with VBG 4
Horizontal operation
Only the special type OGiV âhorizontalâ may be used. Its design and manufacturing process are specifically adapted for this purpose.
Maximum current (Imax) possible without limitation
Float charge voltage
U = 2.25 V/cell ±1% between 10 °C and 45 °C
Temperature compensation: ÎU/ÎT = â0.003 V/K below 10 °C (monthly average)
Float charge current
20â30 mA per 100 Ah
Boost charge
U = 2.35 V/cell, time-limited
Charging time to 92%
6 hours at 1.5 Ă I10 initial current, 2.25 V/cell, after 80% C3 discharge
20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below current-dependent end-of-discharge voltages must be avoided
Recovery after deep discharge
The GEL system allows full recharge and recovery after unintended deep discharges
12+ years (long life)
Service life
Up to 15 years in standby parallel operation
Maintenance
Maintenance-free (no water refilling required during service life)
IEC 60896-2 cycles
>800
elf-discharge
Approx. 2% per month at 20 °C
Operating temperature
-20 °C to +45 °C
Recommended: 10 °C to 30 °C
Short-term: 45 °C to 55 °C
Dimensions according to
DIN 40 737 Part 3
IEC 60896-21
IEC 60896-22
Safety standard / ventilation
DIN EN 50272-2
For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right choice.
They are used for standby power supply in telecommunications equipment, microwave radio stations, data and signalling systems in transport infrastructure, switchgear installations of utility companies, and other applications.
Construction
Positive electrodeRound grid plate with circular grid bars made of corrosion-resistant PbCaSn alloy
Negative electrode
Grid plate in PbCaSn alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l, immobilised as GEL using fumed silica
Container
SAN (styrene-acrylonitrile) in proven battery quality, grey-coloured, UL 94 HB
Lid
SAN, grey-coloured, UL 94 HB
Optionally available in ABS (container and lid), compliant with UL 94 V-0
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Valve
One valve per cell with flame arrestor
Opening pressure approx. 100 mbar, closing pressure approx. 50 mbar
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars with cross-sections of 90, 150 or 300 mmÂČ, or
flexible insulated copper cables with cross-sections of 35, 50, 70, 95 or 120 mmÂČ
Protection class
IP25 according to DIN 40 050, protection against accidental contact in accordance with VBG 4
Horizontal operation
Only the special type OGiV âhorizontalâ may be used. Its design and manufacturing process are specifically adapted for this purpose.
Charging
IU characteristic curveMaximum current (Imax) possible without limitation
Float charge voltage
U = 2.25 V/cell ±1% between 10 °C and 45 °C
Temperature compensation: ÎU/ÎT = â0.003 V/K below 10 °C (monthly average)
Float charge current
20â30 mA per 100 Ah
Boost charge
U = 2.35 V/cell, time-limited
Charging time to 92%
6 hours at 1.5 Ă I10 initial current, 2.25 V/cell, after 80% C3 discharge
Discharge Characteristics
Reference temperature20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below current-dependent end-of-discharge voltages must be avoided
Recovery after deep discharge
The GEL system allows full recharge and recovery after unintended deep discharges
Maintenance
- Every 6 months: Check battery voltage, pilot block voltages and temperatures
- Every 12 months: Record battery voltage, block voltages and temperatures
Operating Characteristics
EUROBAT classification12+ years (long life)
Service life
Up to 15 years in standby parallel operation
Maintenance
Maintenance-free (no water refilling required during service life)
IEC 60896-2 cycles
>800
elf-discharge
Approx. 2% per month at 20 °C
Operating temperature
-20 °C to +45 °C
Recommended: 10 °C to 30 °C
Short-term: 45 °C to 55 °C
Dimensions according to
DIN 40 737 Part 3
Standards and Safety
Testing standardsIEC 60896-21
IEC 60896-22
Safety standard / ventilation
DIN EN 50272-2
Delivery
Batteries are not subject to ADR regulations (road transport), provided the conditions of Special Provision 598 (Chapter 3.3) are fulfilled.Specifications
- Length at mm
- 380.00
- width at mm
- 205.00
- Height at mm
- 385.00
- Weight at kg
- 84.00
- Spannung
- 2
- Capacity Ah
- 125
- Manufacture
- BAE
Reviews (0)
There are no reviews yet.
12 V 5 OGiV 125 PPol
Item No. 0368004
BAE OGiV batteries belong to the highest EUROBAT classification for maintenance-free lead-acid batteries, 12+ long life. For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right
Out of stock
Description
BAE OGiV batteries belong to the highest EUROBAT classification for maintenance-free lead-acid batteries, 12+ long life.
For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right choice.
They are used for standby power supply in telecommunications equipment, microwave radio stations, data and signalling systems in transport infrastructure, switchgear installations of utility companies, and other applications.
Round grid plate with circular grid bars made of corrosion-resistant PbCaSn alloy
Negative electrode
Grid plate in PbCaSn alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l, immobilised as GEL using fumed silica
Container
SAN (styrene-acrylonitrile) in proven battery quality, grey-coloured, UL 94 HB
Lid
SAN, grey-coloured, UL 94 HB
Optionally available in ABS (container and lid), compliant with UL 94 V-0
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Valve
One valve per cell with flame arrestor
Opening pressure approx. 100 mbar, closing pressure approx. 50 mbar
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars with cross-sections of 90, 150 or 300 mmÂČ, or
flexible insulated copper cables with cross-sections of 35, 50, 70, 95 or 120 mmÂČ
Protection class
IP25 according to DIN 40 050, protection against accidental contact in accordance with VBG 4
Horizontal operation
Only the special type OGiV âhorizontalâ may be used. Its design and manufacturing process are specifically adapted for this purpose.
Maximum current (Imax) possible without limitation
Float charge voltage
U = 2.25 V/cell ±1% between 10 °C and 45 °C
Temperature compensation: ÎU/ÎT = â0.003 V/K below 10 °C (monthly average)
Float charge current
20â30 mA per 100 Ah
Boost charge
U = 2.35 V/cell, time-limited
Charging time to 92%
6 hours at 1.5 Ă I10 initial current, 2.25 V/cell, after 80% C3 discharge
20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below current-dependent end-of-discharge voltages must be avoided
Recovery after deep discharge
The GEL system allows full recharge and recovery after unintended deep discharges
12+ years (long life)
Service life
Up to 15 years in standby parallel operation
Maintenance
Maintenance-free (no water refilling required during service life)
IEC 60896-2 cycles
>800
elf-discharge
Approx. 2% per month at 20 °C
Operating temperature
-20 °C to +45 °C
Recommended: 10 °C to 30 °C
Short-term: 45 °C to 55 °C
Dimensions according to
DIN 40 737 Part 3
IEC 60896-21
IEC 60896-22
Safety standard / ventilation
DIN EN 50272-2
For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right choice.
They are used for standby power supply in telecommunications equipment, microwave radio stations, data and signalling systems in transport infrastructure, switchgear installations of utility companies, and other applications.
Construction
Positive electrodeRound grid plate with circular grid bars made of corrosion-resistant PbCaSn alloy
Negative electrode
Grid plate in PbCaSn alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l, immobilised as GEL using fumed silica
Container
SAN (styrene-acrylonitrile) in proven battery quality, grey-coloured, UL 94 HB
Lid
SAN, grey-coloured, UL 94 HB
Optionally available in ABS (container and lid), compliant with UL 94 V-0
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Valve
One valve per cell with flame arrestor
Opening pressure approx. 100 mbar, closing pressure approx. 50 mbar
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars with cross-sections of 90, 150 or 300 mmÂČ, or
flexible insulated copper cables with cross-sections of 35, 50, 70, 95 or 120 mmÂČ
Protection class
IP25 according to DIN 40 050, protection against accidental contact in accordance with VBG 4
Horizontal operation
Only the special type OGiV âhorizontalâ may be used. Its design and manufacturing process are specifically adapted for this purpose.
Charging
IU characteristic curveMaximum current (Imax) possible without limitation
Float charge voltage
U = 2.25 V/cell ±1% between 10 °C and 45 °C
Temperature compensation: ÎU/ÎT = â0.003 V/K below 10 °C (monthly average)
Float charge current
20â30 mA per 100 Ah
Boost charge
U = 2.35 V/cell, time-limited
Charging time to 92%
6 hours at 1.5 Ă I10 initial current, 2.25 V/cell, after 80% C3 discharge
Discharge Characteristics
Reference temperature20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below current-dependent end-of-discharge voltages must be avoided
Recovery after deep discharge
The GEL system allows full recharge and recovery after unintended deep discharges
Maintenance
- Every 6 months: Check battery voltage, pilot block voltages and temperatures
- Every 12 months: Record battery voltage, block voltages and temperatures
Operating Characteristics
EUROBAT classification12+ years (long life)
Service life
Up to 15 years in standby parallel operation
Maintenance
Maintenance-free (no water refilling required during service life)
IEC 60896-2 cycles
>800
elf-discharge
Approx. 2% per month at 20 °C
Operating temperature
-20 °C to +45 °C
Recommended: 10 °C to 30 °C
Short-term: 45 °C to 55 °C
Dimensions according to
DIN 40 737 Part 3
Standards and Safety
Testing standardsIEC 60896-21
IEC 60896-22
Safety standard / ventilation
DIN EN 50272-2
Delivery
Batteries are not subject to ADR regulations (road transport), provided the conditions of Special Provision 598 (Chapter 3.3) are fulfilled.Specifications
- Length at mm
- 380.00
- width at mm
- 205.00
- Height at mm
- 385.00
- Weight at kg
- 84.00
- Spannung
- 2
- Capacity Ah
- 125
- Manufacture
- BAE
Reviews (0)
There are no reviews yet.