Top of the page

6 V 10 OGiV 250 PPol

Item No. 0368018
BAE OGiV batteries belong to the highest EUROBAT classification for maintenance-free lead-acid batteries, 12+ long life. For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right
Out of stock

Description

BAE OGiV batteries belong to the highest EUROBAT classification for maintenance-free lead-acid batteries, 12+ long life.
For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right choice.
They are used for standby power supply in telecommunications equipment, microwave radio stations, data and signalling systems in transport infrastructure, switchgear installations of utility companies, and other applications.

Construction

Positive electrode
Round grid plate with circular grid bars made of corrosion-resistant PbCaSn alloy
Negative electrode
Grid plate in PbCaSn alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l, immobilised as GEL using fumed silica
Container
SAN (styrene-acrylonitrile) in proven battery quality, grey-coloured, UL 94 HB
Lid
SAN, grey-coloured, UL 94 HB
Optionally available in ABS (container and lid), compliant with UL 94 V-0
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Valve
One valve per cell with flame arrestor
Opening pressure approx. 100 mbar, closing pressure approx. 50 mbar
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars with cross-sections of 90, 150 or 300 mmÂČ, or
flexible insulated copper cables with cross-sections of 35, 50, 70, 95 or 120 mmÂČ
Protection class
IP25 according to DIN 40 050, protection against accidental contact in accordance with VBG 4
Horizontal operation
Only the special type OGiV “horizontal” may be used. Its design and manufacturing process are specifically adapted for this purpose.

Charging

IU characteristic curve
Maximum current (Imax) possible without limitation
Float charge voltage
U = 2.25 V/cell ±1% between 10 °C and 45 °C
Temperature compensation: ΔU/ΔT = −0.003 V/K below 10 °C (monthly average)
Float charge current
20–30 mA per 100 Ah
Boost charge
U = 2.35 V/cell, time-limited
Charging time to 92%
6 hours at 1.5 × I10 initial current, 2.25 V/cell, after 80% C3 discharge

Discharge Characteristics

Reference temperature
20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below current-dependent end-of-discharge voltages must be avoided
Recovery after deep discharge
The GEL system allows full recharge and recovery after unintended deep discharges

Maintenance

  • Every 6 months: Check battery voltage, pilot block voltages and temperatures
  • Every 12 months: Record battery voltage, block voltages and temperatures

Operating Characteristics

EUROBAT classification
12+ years (long life)
Service life
Up to 15 years in standby parallel operation
Maintenance
Maintenance-free (no water refilling required during service life)
IEC 60896-2 cycles
>800
elf-discharge
Approx. 2% per month at 20 °C
Operating temperature
-20 °C to +45 °C
Recommended: 10 °C to 30 °C
Short-term: 45 °C to 55 °C
Dimensions according to
DIN 40 737 Part 3

Standards and Safety

Testing standards
IEC 60896-21
IEC 60896-22
Safety standard / ventilation
DIN EN 50272-2

Delivery

Batteries are not subject to ADR regulations (road transport), provided the conditions of Special Provision 598 (Chapter 3.3) are fulfilled.

Specifications

Length at mm
380.00
width at mm
205.00
Height at mm
385.00
Weight at kg
78.00
Spannung
6
Capacity Ah
250
Manufacture
BAE

Reviews (0)

There are no reviews yet.

6 V 10 OGiV 250 PPol

Item No. 0368018
BAE OGiV batteries belong to the highest EUROBAT classification for maintenance-free lead-acid batteries, 12+ long life. For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right
Out of stock

Description

BAE OGiV batteries belong to the highest EUROBAT classification for maintenance-free lead-acid batteries, 12+ long life.
For applications with the highest requirements in terms of operational reliability and bridging times between 15 minutes and several hours, BAE OGiV batteries are the right choice.
They are used for standby power supply in telecommunications equipment, microwave radio stations, data and signalling systems in transport infrastructure, switchgear installations of utility companies, and other applications.

Construction

Positive electrode
Round grid plate with circular grid bars made of corrosion-resistant PbCaSn alloy
Negative electrode
Grid plate in PbCaSn alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l, immobilised as GEL using fumed silica
Container
SAN (styrene-acrylonitrile) in proven battery quality, grey-coloured, UL 94 HB
Lid
SAN, grey-coloured, UL 94 HB
Optionally available in ABS (container and lid), compliant with UL 94 V-0
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Valve
One valve per cell with flame arrestor
Opening pressure approx. 100 mbar, closing pressure approx. 50 mbar
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars with cross-sections of 90, 150 or 300 mmÂČ, or
flexible insulated copper cables with cross-sections of 35, 50, 70, 95 or 120 mmÂČ
Protection class
IP25 according to DIN 40 050, protection against accidental contact in accordance with VBG 4
Horizontal operation
Only the special type OGiV “horizontal” may be used. Its design and manufacturing process are specifically adapted for this purpose.

Charging

IU characteristic curve
Maximum current (Imax) possible without limitation
Float charge voltage
U = 2.25 V/cell ±1% between 10 °C and 45 °C
Temperature compensation: ΔU/ΔT = −0.003 V/K below 10 °C (monthly average)
Float charge current
20–30 mA per 100 Ah
Boost charge
U = 2.35 V/cell, time-limited
Charging time to 92%
6 hours at 1.5 × I10 initial current, 2.25 V/cell, after 80% C3 discharge

Discharge Characteristics

Reference temperature
20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below current-dependent end-of-discharge voltages must be avoided
Recovery after deep discharge
The GEL system allows full recharge and recovery after unintended deep discharges

Maintenance

  • Every 6 months: Check battery voltage, pilot block voltages and temperatures
  • Every 12 months: Record battery voltage, block voltages and temperatures

Operating Characteristics

EUROBAT classification
12+ years (long life)
Service life
Up to 15 years in standby parallel operation
Maintenance
Maintenance-free (no water refilling required during service life)
IEC 60896-2 cycles
>800
elf-discharge
Approx. 2% per month at 20 °C
Operating temperature
-20 °C to +45 °C
Recommended: 10 °C to 30 °C
Short-term: 45 °C to 55 °C
Dimensions according to
DIN 40 737 Part 3

Standards and Safety

Testing standards
IEC 60896-21
IEC 60896-22
Safety standard / ventilation
DIN EN 50272-2

Delivery

Batteries are not subject to ADR regulations (road transport), provided the conditions of Special Provision 598 (Chapter 3.3) are fulfilled.

Specifications

Length at mm
380.00
width at mm
205.00
Height at mm
385.00
Weight at kg
78.00
Spannung
6
Capacity Ah
250
Manufacture
BAE

Reviews (0)

There are no reviews yet.