Block 12 V 3 OPzV 150 PPol
Description
BAE OPzV batteries exceed the highest EUROBAT classification for maintenance-free lead-acid batteries, Long Life 12+.
For applications with high demands on operational reliability and bridging times from 1 hour up to more than 10 hours, BAE SECURA OPzV batteries are the right choice.
They are used for standby power supply in telecommunications equipment, microwave radio stations, emergency lighting systems, and other installations.
Construction
Positive electrode
Tubular plate with polyester gauntlet and solid grids made of corrosion-resistant PbCaSn alloy
Negative electrode
Grid plate in PbCaSn alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l, immobilised as GEL using fumed silica
Container
Impact-resistant, halogen-free SAN (styrene-acrylonitrile), grey-coloured, UL 94 HB
Lid
Impact-resistant, halogen-free SAN, grey-coloured, UL 94 HB
Optionally available in ABS (container and lid), compliant with UL 94 V-0
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Valve
One valve per cell with flame arrestor
Opening pressure approx. 100 mbar, closing pressure approx. 50 mbar
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars (90 or 150 mmÂČ) or flexible insulated copper cables (35, 50, 70, 95 or 120 mmÂČ)
Protection class
IP25 according to DIN 40050, protection against accidental contact in accordance with VBG 4
Horizontal operation
Only the special type OPzV âhorizontalâ may be used. Its design and manufacturing process are specifically adapted for this purpose.
Charging
IU characteristic curve
Maximum current (Imax) possible without limitation
Float charge current
20â30 mA per 100 Ah
Boost charge
2.35 to 2.40 V/cell, time-limited
Charging time to 90%
6 hours at 1.5 Ă I10 initial current, 2.25 V/cell, after 80% C3 discharge
Float charge voltage
2.25 V/cell ±1% between 10 °C and 45 °C
Temperature compensation: â0.003 V/K below 10 °C (monthly average)
Discharge Characteristics
Reference temperature
20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below the current-dependent end-of-discharge voltages must be avoided
Recovery after deep discharge
The GEL system allows complete recharge and recovery after unintended deep discharges
Maintenance
- Every 6 months: Check battery voltage, pilot block voltages and temperatures
- Every 12 months: Record battery voltage, block voltages and temperatures
Operating Characteristics
EUROBAT classification
Long Life 12+
Service life
18 years at 20 °C
Maintenance
Maintenance-free (no water refilling required during service life)
Recovery after deep discharge
Very good
Self-discharge
Approx. 2% per month at 20 °C
Operating temperature
-20 °C to +45 °C
Recommended: 10 °C to 30 °C
Short-term: 45 °C to 55 °C
Standard
DIN 40 744
Standards and Safety
Testing standards
IEC 60896-21
IEC 60896-22
Safety standard / ventilation
DIN EN 50272-2
Delivery
Batteries are not subject to ADR regulations (road transport), provided the conditions of Special Provision 598 (Chapter 3.3) are met.
Specifications
- Length at mm
- 380.00
- width at mm
- 205.00
- Height at mm
- 385.00
- Weight at kg
- 74.20
- Spannung
- 12
- Capacity Ah
- 150
- Manufacture
- BAE
Reviews (0)
There are no reviews yet.
Block 12 V 3 OPzV 150 PPol
Description
BAE OPzV batteries exceed the highest EUROBAT classification for maintenance-free lead-acid batteries, Long Life 12+.
For applications with high demands on operational reliability and bridging times from 1 hour up to more than 10 hours, BAE SECURA OPzV batteries are the right choice.
They are used for standby power supply in telecommunications equipment, microwave radio stations, emergency lighting systems, and other installations.
Construction
Positive electrode
Tubular plate with polyester gauntlet and solid grids made of corrosion-resistant PbCaSn alloy
Negative electrode
Grid plate in PbCaSn alloy with long-life expander
Separation
Microporous separator
Electrolyte
Sulphuric acid with a density of 1.24 kg/l, immobilised as GEL using fumed silica
Container
Impact-resistant, halogen-free SAN (styrene-acrylonitrile), grey-coloured, UL 94 HB
Lid
Impact-resistant, halogen-free SAN, grey-coloured, UL 94 HB
Optionally available in ABS (container and lid), compliant with UL 94 V-0
Blocks with blind cells
4 V, 6 V, 8 V, 10 V
Valve
One valve per cell with flame arrestor
Opening pressure approx. 100 mbar, closing pressure approx. 50 mbar
Terminal bushing
100% gas- and electrolyte-tight, sliding, plastic-overmolded tank pole
Terminal design
M10 brass insert
Connectors
Insulated copper busbars (90 or 150 mmÂČ) or flexible insulated copper cables (35, 50, 70, 95 or 120 mmÂČ)
Protection class
IP25 according to DIN 40050, protection against accidental contact in accordance with VBG 4
Horizontal operation
Only the special type OPzV âhorizontalâ may be used. Its design and manufacturing process are specifically adapted for this purpose.
Charging
IU characteristic curve
Maximum current (Imax) possible without limitation
Float charge current
20â30 mA per 100 Ah
Boost charge
2.35 to 2.40 V/cell, time-limited
Charging time to 90%
6 hours at 1.5 Ă I10 initial current, 2.25 V/cell, after 80% C3 discharge
Float charge voltage
2.25 V/cell ±1% between 10 °C and 45 °C
Temperature compensation: â0.003 V/K below 10 °C (monthly average)
Discharge Characteristics
Reference temperature
20 °C
Initial capacity
100%
Depth of discharge
Normally up to 80%
Deep discharge
Discharges beyond 80% and below the current-dependent end-of-discharge voltages must be avoided
Recovery after deep discharge
The GEL system allows complete recharge and recovery after unintended deep discharges
Maintenance
- Every 6 months: Check battery voltage, pilot block voltages and temperatures
- Every 12 months: Record battery voltage, block voltages and temperatures
Operating Characteristics
EUROBAT classification
Long Life 12+
Service life
18 years at 20 °C
Maintenance
Maintenance-free (no water refilling required during service life)
Recovery after deep discharge
Very good
Self-discharge
Approx. 2% per month at 20 °C
Operating temperature
-20 °C to +45 °C
Recommended: 10 °C to 30 °C
Short-term: 45 °C to 55 °C
Standard
DIN 40 744
Standards and Safety
Testing standards
IEC 60896-21
IEC 60896-22
Safety standard / ventilation
DIN EN 50272-2
Delivery
Batteries are not subject to ADR regulations (road transport), provided the conditions of Special Provision 598 (Chapter 3.3) are met.
Specifications
- Length at mm
- 380.00
- width at mm
- 205.00
- Height at mm
- 385.00
- Weight at kg
- 74.20
- Spannung
- 12
- Capacity Ah
- 150
- Manufacture
- BAE